Crack mapping and quantification to support epoxy injection repair programs — identifying crack widths, lengths, and injection port spacing.
ACI 224.1R, ASTM C881, ASTM C882, ICRI Technical Guidelines 310.2R, ACI 318
Post-injection core (at EOR request): drill through crack to verify fill continuity. Maintain injection log: port locations, materials, pressures, and volumes injected per crack.