FACADES
MAPPING & QUANTIFICATION
← All Services
EnvelopeCSI 07 42 00 / 07 44 00
SCOPE OF WORK

Full-envelope aerial facade surveys providing complete documentation of multi-story building exteriors from top to grade level.

Applicable Standards

ASTM E2568 (EIFS), EIMA, NFPA 285 (MCM fire), AAMA 501.2/503 (water testing), ASTM E1105, ASTM E783, Secretary of Interior's Standards (historic), OSHA 1926 Subpart R

Facade Condition Assessment
  • Visual survey from swing stage / rope access / scaffold: sounding, probing, photographic documentation.
  • Pull-out / adhesion testing (ASTM E488 / D4541): minimum 3 per facade elevation per system.
  • IR thermography: conduct survey at 10°F+ delta-T to map moisture, delaminations, air leakage paths.
  • Water infiltration testing: AAMA 501.2 hose test, ASTM E1105 static or ASTM E547 dynamic chamber.
  • Produce Facade Condition Assessment Report with elevation deficiency maps and capital planning model.
EIFS Repair & Replacement
  • Sound all EIFS; map delaminated, wet, and deteriorated zones; submit repair plan for approval.
  • Remove damaged EIFS; repair substrate (sheathing, WRB, framing); install new drainable EIFS per EIMA.
  • Approved systems: Dryvit Outsulation MD, Sto PowerWall Plus, Parex; all with drainage plane.
  • Flash all EIFS terminations: drainage gap, weep screed, sealant per ASTM E2568.
MCM / Metal Panel Systems
  • Inspect all MCM panel connections, seams, and sealant joints; probe for corrosion of subframe.
  • NFPA 285 compliance review: verify existing system meets current fire test requirements.
  • Replace corroded fasteners with stainless steel; apply corrosion inhibitor to subframe.
  • Replace damaged panels: source color-match from manufacturer; mock-up sample approval required.
Stone & Precast Facade
  • Sound all stone panels; document anchor condition; test representative anchors per ASTM E488.
  • Chemical cleaning per species-appropriate method; test patch required before production.
  • Repair cracks: epoxy injection for structural; polyurethane for cosmetic.
  • Anchor replacement: Type 316 SS; epoxy-grouted; capacity per EOR design.
Access & Occupied Building Protocols
  • Swing stage: rigging plan by licensed engineer; daily pre-use inspection; OSHA 1926.552.
  • Tenant notification: minimum 2 weeks advance notice for work adjacent to occupied space.
  • Chemical/VOC notification: 48-hour notice before applying products above OSHA action threshold.
Explore all services
MORE SERVICES
01
Concrete Repair
02
Coatings
03
Masonry
04
Sealants
05
Expansion Joints
06
Epoxy Injection
07
Grout Injection
08
Foundations
09
CMU
10
CIP Concrete
11
Precast Concrete
12
Steel
13
Facades
14
Windows
15
Siding
16
Paint