HomeServices › Grout Injection
GROUT INJECTION
MAPPING & QUANTIFICATION
← All Services
RepairCSI 03 11 00 / 31 09 00
SCOPE OF WORK

Aerial identification and mapping of voids, honeycombs, and cavities in concrete and masonry requiring grout injection remediation.

Applicable Standards

ACI 351.1R, ASTM C827, ASTM C1107, ASTM C939, ASTM D4218 (polyurethane systems)

Void Investigation
  • GPR scan to locate and map subsurface voids before drilling.
  • Probe drilling at representative locations to confirm void depth and extent.
  • Document void locations, estimated volumes, and access conditions in written report.
Cementitious Grout Injection
  • Non-shrink cementitious grout per ACI 351.1R: flowable or thixotropic per application.
  • Drill grout holes at specified pattern and depth per grouting plan.
  • Pressure test each hole before grouting; monitor grout take during injection.
  • QC: cube specimens at minimum 1 per 10 CY; flow per ASTM C939.
Chemical Grout / Polyurethane Injection
  • PU foam injection (Avanti AV-202 or equal) for slab lifting and soil void filling.
  • Chemical grout (acrylate or PU) for water-stopping and soil consolidation.
  • Curtain grouting: inject into soil or rock to form vertical water-stopping curtain.
Slab Lifting (Slabjacking)
  • Expanding PU foam injection under settled slabs to restore grade.
  • Mark drill hole pattern; drill 1"–2" holes at specified spacing.
  • Inject foam until slab reaches target elevation; patch all holes after completion.
QC and Verification
  • Grout take log per hole: volume, pressure, and refusal criteria documented.
  • Post-injection GPR rescan or probe drilling to verify void fill.
  • Slab elevation survey before and after lifting to document results.
Explore all services
MORE SERVICES
01
Concrete Repair
02
Coatings
03
Masonry
04
Sealants
05
Expansion Joints
06
Epoxy Injection
07
Grout Injection
08
Foundations
09
CMU
10
CIP Concrete
11
Precast Concrete
12
Steel
13
Facades
14
Windows
15
Siding
16
Paint