Panel-by-panel aerial documentation of precast concrete facades — connection points, panel joints, and surface deterioration mapping.
PCI MNL-116, ACI 318, ACI 546R, ICRI 310.2R, ASTM C881, ASTM E488 (anchor pull-out)
Remove all existing sealants; install new backer rod; apply structural silicone or polyurethane sealant. Movement analysis required for large precast panels: confirm sealant movement capacity matches joint demand.
Source match from original precaster or approved substitute; submit mock-up for Owner approval. Erection per EOR-approved connection design; match panel finish and color to adjacent units.